Request For Quotation

Request For Information

Temperature Logger-DBSA710A


Category: DaqLink
Manufacturer: Fourtec show products

Stand-alone loggers measuring up to 6 channels

The DaqLink product line consists of stand-alone data loggers with USB interface, offering rich functionality in a compact size. With built-in temperature and humidity sensors, plus four external inputs each capable of measuring voltage, current, temperature, pulse and frequency, the DaqLink provides a cost-effective and accurate data logging solution for a variety of industrial applications. For continuous indoor or outdoor monitoring, the DaqLink data logger is the tool of choice.

Description

The DaqLink Temp logger is a stand-alone device with USB interface, offering rich functionality in a compact size. With a built-in temperature sensor plus four external inputs each capable of measuring voltage, current, temperature, pulse and frequency, the DaqLink Temp provides a cost-effective and accurate data logging solution. For continuous indoor or outdoor monitoring, the DaqLink is the tool of choice.

Key product Benefits:

  • Up to 5 measuring inputs with 16-bit resolution
  • Real-time data streaming via USB to PC or cyclic storage to onboard memory
  • Onsite data monitoring with two-row LCD
  • Keypad with Run/Pause logging option
  • Four level alarm configuration with email/SMS notification and onboard alarm buzzer
  • Long-lasting rechargeable battery for standalone monitoring
  • Supported by DataSuite software for data analysis and device setup

Features

INPUT TYPES

INPUT TYPES

 

• Range: 4 to 20 mA

• Resolution: 47.6 μA

• Accuracy: ±0.5 %

• Loop impedance: 21 Ω

0 to 50 mV

 

• Range: 0 to 50 mV

• Resolution: 37 μV

• Accuracy: ±0.5 %

• Input impedance: 25 MΩ

• Max voltage: 3.2 V

0 to 1 V

 

• Range: 0 to 1 V

• Resolution: 200 μV

• Accuracy: ±0.5 %

• Input impedance: 25 MΩ

• Max voltage: 3.2 V

Temperature PT-100 (2-wires)

 

• Range: -200 to 400 ˚C

• Resolution: 0.1 ˚C

• Accuracy:
-200 to -60 ˚C: ±0.5 %

-60 to 60 ˚C: ±0.3 ˚C

60 to 400 ˚C: ±0.5 %

Temperature Thermocouple J

 

• Range: -200 to 1,000 ˚C

• Resolution: 0.1 ˚C

• Accuracy:
-200 to -60 ˚C: ±0.5 %

-60 to 60 ˚C: ±0.5 ˚C

60 to 1,000 ˚C: ±0.5 %

• Cold junction compensation error: ±0.3 ºC

Temperature Thermocouple K

 

• Range: -200 to 1,000 ºC

• Resolution: 0.1 ˚C

• Accuracy:
-200 to -60 ˚C: ±0.5 %

-60 to 60 ˚C: ±0.5 ˚C

60 to 1,000 ˚C: ±0.5 %

• Cold junction compensation error: ±0.3 ˚C

Temperature Thermocouple T

 

• Range: -200 to 400 ˚C

• Resolution: 0.1 ˚C

• Accuracy:
-200 to -60 ˚C: ±0.5 %

-60 to 60 ˚C: ±0.5 ˚C

60 to 400 ˚C: ±0.5 %

• Cold junction compensation error: ±0.3 ˚C

Frequency (input 4 only)

• Range: 20 Hz to 4 KHz

• Input signal: 0 to 5 V

• Input impedance: 470 Ω

Pulse Counter (input 4 only)

 

• Range: 1 to 65,536 counts

• Resolution: 1 count

• Frequency range: 0 to 4,000 Hz

• Input signal: 0 to 3.2 V

• Input impedance: 470 Ω

Contact

• Range: Open/Closed

Internal Temperature

 

• Range: -20 to 50 ˚C

• Accuracy: ±0.3 ˚C

• Resolution: 0.1 ˚C

 

OUTPUTS

External Power Excitation (transducers usage)

• 12 VDC @ 300 mA

• Reset fuse overload protection

Dry Contact Alarm Output

 

• Open collector

• Close position resistance: 50 Ω

• Max. Load: 50 mA, 3 V DC

LOGGER SAMPLING FEATURES

 

• Memory capacity: ~59,000 samples (depending on logger configuration)

• Sampling rate: One every second to one every 18 hours

• Channel separation: 80 dB

 

HARDWARE SPECIFICATIONS

Display

 

• 2-row LCD

• 16 character display

Memory Modes

 

• Cyclic/Non-cyclic

• Push to Run

• Pause logging

Power Supply

 

• Internal rechargeable 4.8 V, 800 mAh NiMH battery

• External 12 V DC input @ 300 mA 3.6 VA

• Battery Life: Up to 10 months, depending on logger configuration

Operating Temperature Range

-20 to 50 ˚C

PC Communication

• USB 2.0 compliance

• Mini USB type B cable

Casing

 

• Plastic PC-ABS

• Dimensions: 104 x 93 x 27 mm

• Weight: 153 g

• Supports table and wall mounting

Man Machine Interface

• Two-button keypad operation

Standards Compliance

• CE, FCC, IC Canada

• Water and dust proof: IP54

 

Applications

Applications
Industrial Processes
Heavy Industry Productions:Aerospace,Chemicals & Plastics,Industrial machinery,Mass Transit,Steel and oil refining production,Automotive,Manufacturing,Clean rooms,Mining

  • Pharmaceutical:Pharma Clean Rooms,Pharma Production Area,Pharma Shipping,Pharma Warehouse Storage,Pharma Laboratories,Pharma Refrigerators,Validations

Building Monitoring/HVAC/Energy Usage

  • Museums:Museum Archives,Museum Shipping,Museum Climate Monitoring,Museum Warehouse Storage
  • School Universities:School Refrigerators,School Laboratories,Research,School HVAC,School Libraries Archives
  • Warehouses Storage:Food storage,Pharma storage,Agriculture Storage,Electronic Components,Dry Storage

Refrigeration and Freezer (including Food & Medical Storage and Transportation)
With both food and medicine, it is increasingly important for manufacturers, suppliers and end users to have verifiable evidence that correct environmental conditions have been provided from the moment of manufacture to the time that the goods are used.

  • Food:Food laboratories,Pasteurization,Food refrigerators,Food Warehouse Storage,Food Ovens,Production floor,Food Shipping
  • Cold Chain:Packaging,Tansportation,Cold Chain Warehouse Storage
  • Hospital Health:Blood Bank Monitoring,Heat Ventilation Air Conditioning, Medical Equipment,Shipping Samples,Drug Storage,Hospital Laboratories,Refrigerator Monitoring,Surgical Suites
  • Transportation:Shipping,Warehouse Storage
  • Laboratories:Laboratory Ovens,Incubators,Freezers,Autoclaves,Lab Refrigerators,Lab Climate Monitoring

Agriculture, Horticulture, Environmental Studies

  • Agriculture solutions:Green Houses, Agriculture Shipping, Agriculture Warehouse Storage

Software

DataSuite Software for DataNet

DataSuite-DN

Product Part Number: DataSuite-DN
Software Activation: User must activate software using unique serial number purchased from Fourtec. 30-day trial period also available.
Order shipped with: Software CD and mini-USB communication cable
System Requirements
Software

Windows XP SP3, Windows Vista, Windows 7 (32-bit and 64-bit), Windows 8.1 (32-bit and 64-bit)

Minimum screen resolution: 1024 x 768 (800 x 600 not supported)

Hardware Pentium 4, 2.0 GHz or better
512 MB RAM
250 MB available disk space for the DataSuite application

DS-CFR-DN

Product Part Number: DS-CFR-DN
Software Activation: User must activate software using unique serial number purchased from Fourtec. 30-day trial period also available.
Order shipped with: Software CD for DatPass and DataSuite installation, and mini-USB communication cable
System Requirements

Windows XP SP3, Vista, 7 (32 and 64-bit)
Pentium 4 2.0 GHz or better
512 MB RAM
250 MB available disk space